Miele Tx3587

19 manual(s) 10 error code(s) 0 guide(s)

πŸ“– Service Manuals

Also covers: typevariants

⚑ Miele Error Codes

F02
Drain pump issue β€” not draining properly
F04
Water inlet issue β€” not filling
F05
Water temperature issue
F08
Door lock issue
F11
Water leak detected
F13
Heating issue β€” not reaching temperature
F22
Water quality sensor issue
F32
Rinse aid sensor issue
F42
Salt sensor β€” add salt
F52
Door not fully closed

βš™οΈ Component Test Values

heating element (general)

Normal: 0.0–120.0Ξ© Any component that consumes power

solenoid (on off)

Normal: 10.0–NoneΞ© On/off solenoids > 10Ξ©

solenoid (regulating)

Normal: 0.0–10.0Ξ© Regulating solenoids < 10Ξ©

motor (general)

Normal: 10.0–200.0Ξ© General appliance motors

water inlet valve (general)

Normal: 500.0–1500.0Ξ© Water inlet valve

switch (door switch)

Normal: 0.0–0.0Ξ© 0Ξ© when closed, OL when open

switch (bimetal switch)

Normal: 0.0–1.0Ξ© Bi-metal switch

thermostat (general)

Normal: 0.0–0.0Ξ© 0Ξ© when closed, OL when open

thermistor (general)

Normal: 2000.0–220000.0Ξ© Check spec for your specific thermistor. NTC: Ξ© decreases as temp increases. PTC

fuse (general)

Normal: 0.0–1.0Ξ© < 1Ξ© when good, OL when blown