Miele Cva

19 manual(s) 10 error code(s) 0 guide(s)

📖 Service Manuals

⚡ Miele Error Codes

F02
Drain pump issue — not draining properly
F04
Water inlet issue — not filling
F05
Water temperature issue
F08
Door lock issue
F11
Water leak detected
F13
Heating issue — not reaching temperature
F22
Water quality sensor issue
F32
Rinse aid sensor issue
F42
Salt sensor — add salt
F52
Door not fully closed

⚙️ Component Test Values

heating element (general)

Normal: 0.0–120.0Ω Any component that consumes power

solenoid (on off)

Normal: 10.0–NoneΩ On/off solenoids > 10Ω

solenoid (regulating)

Normal: 0.0–10.0Ω Regulating solenoids < 10Ω

motor (general)

Normal: 10.0–200.0Ω General appliance motors

water inlet valve (general)

Normal: 500.0–1500.0Ω Water inlet valve

switch (door switch)

Normal: 0.0–0.0Ω 0Ω when closed, OL when open

switch (bimetal switch)

Normal: 0.0–1.0Ω Bi-metal switch

thermostat (general)

Normal: 0.0–0.0Ω 0Ω when closed, OL when open

thermistor (general)

Normal: 2000.0–220000.0Ω Check spec for your specific thermistor. NTC: Ω decreases as temp increases. PTC

fuse (general)

Normal: 0.0–1.0Ω < 1Ω when good, OL when blown