📡 Samsung microwave displays H1 or H2 error (magnetron)
Step-by-step troubleshooting guide — 5 steps, Microwave.
🔧 Troubleshooting Steps
- ⚠️ DISCONNECT POWER AND DISCHARGE THE HIGH-VOLTAGE CAPACITOR (1μF/2000V) — this is lethal. Use a 1kΩ resistor to bleed the cap
✓ Expected: Capacitor discharged, 0V reading
- H1 = magnetron not heating. Check the magnetron filament with a multimeter — should read ~0.5-1Ω between the two filament pins
✓ Expected: Filament resistance in range
- If the filament is open, replace the magnetron. Match the part number exactly — microwave magnetrons are model-specific
✓ Expected: New magnetron installed
- H2 = high-voltage transformer fault. Check the HV transformer secondary winding for open circuit
✓ Expected: Continuity through secondary winding
- Check the rectifier diode and HV capacitor while you have the cover off — both are common simultaneous failures
✓ Expected: Diode shows one-way continuity, cap holds charge