🔧 Troubleshooting Steps
- Measure the heating element resistance. Should read 10-30Ω. Infinite = open, replace element
✓ Expected: 10-30Ω
- Check the thermal cutoff (one-way thermal fuse). Should read 0Ω. Open = blown, replace. DO NOT replace without finding the overheating cause
✓ Expected: 0Ω — cutoff intact
- Check the high-limit thermostat. Should read continuity at room temperature. Open = replace
✓ Expected: Continuity at room temp
- If all components test good, check for 240V at the element during a heat cycle. No 240V = control board relay issue
✓ Expected: 240V AC at element
- Check the vent for lint restriction. A blocked vent causes the dryer to overheat, which can blow the thermal cutoff. Clean the entire vent path from dryer to outside
✓ Expected: Vent clear, good airflow at outside vent