Home

♨️ GE dryer displays F11 error (no heat, electric)

Step-by-step troubleshooting guide — 5 steps, Dryer.

🔧 Troubleshooting Steps

  1. Measure the heating element resistance. Should read 10-30Ω. Infinite = open, replace element
    ✓ Expected: 10-30Ω
  2. Check the thermal cutoff (one-way thermal fuse). Should read 0Ω. Open = blown, replace. DO NOT replace without finding the overheating cause
    ✓ Expected: 0Ω — cutoff intact
  3. Check the high-limit thermostat. Should read continuity at room temperature. Open = replace
    ✓ Expected: Continuity at room temp
  4. If all components test good, check for 240V at the element during a heat cycle. No 240V = control board relay issue
    ✓ Expected: 240V AC at element
  5. Check the vent for lint restriction. A blocked vent causes the dryer to overheat, which can blow the thermal cutoff. Clean the entire vent path from dryer to outside
    ✓ Expected: Vent clear, good airflow at outside vent